App index 24 vdc/ac power supply operaton (/p1), Calbraton correcton (/cc1), Header prntout (/bt1) – Yokogawa µR20000 User Manual
Page 245
12-17
IM 04P02B01-01E
Spec
fcat
ons
1
2
3
4
5
6
7
8
9
10
11
12
App
Index
24 VDC/AC Power Supply Operaton (/P1)
Item
Specfcatons
Rated supply voltage
24 VDC/AC
Allowable power supply voltage range
21.6 to 26.4 VDC/AC
Withstand voltage
1000 VAC at 50/60 Hz for one minute (between the power terminal and the ground terminal)
Rated power supply frequency
50/60 Hz (for AC operation)
Allowable power supply frequency range
50 Hz ± 2% or 60 Hz ± 2% (for AC operation)
Effects of power supply voltage fluctuation
The fluctuation in the measured values is within ±1 digit and that in the recording is within ±0.1% in
the recording span for the 21.6 to 26.4 VAC/DC range.
Effects of power supply frequency fluctuation
The fluctuation in the measured values and recording is ±(0.1% of rdg + 1 digit) at the rated
frequency ±2 Hz.
Rated power
35 VA (for DC) or 45 VA (for AC)
Power consumption
Model
24 VDC
24 VAC
Maxmum
1 to 4 pen models
Approx. 9 VA*
Approx. 17 VA*
Approx. 45 VA
6 to 24 dot models
Approx. 10 VA*
Approx. 18 VA*
Approx. 45 VA
* When balanced
Calbraton Correcton (/CC1)
Item
Specfcatons
Number of calibration points 2 to 16 (can be specified for each channel)
Correction mode
Revise or absolute value (can be specified for each channel)
Correctable range
DC input (DC voltage, TC, and RTD) and linear scaling (DC voltage, TC, RTD, and 1-5V)
(Not allowed on ON/OFF input (including linear scaling), delta computation, square root
computation, and computation channels)
Correction range
• (1
st
correction point + 1
st
correction value) < (2
nd
correction point + 2
nd
correction value) < ...
• Corrected value (revise value: correction point + correction value, absolute value: correction
value) within the measurable range and scaling range (–5% to 105% or –20000 to 30000) of
each input range
• Setting limits
Left span (0%) < Right span (100%)
Left scale (0%) < Right scale (100%)
Others
Calibration correction and bias functions cannot be used simultaneously (common to all channels)
Header Prntout (/BT1)
Item
Specfcatons
Printout function
When recording starts or stops, prints out the batch name, comment, date/time, and chart speed.
Messages can also be printed out including measured values*.
Printed items
Recording start/recording end printouts
Batch name: Batch number (up to 26 characters) and lot number (4 or 6 digit number, or Off)
Comment (up to 64 characters x 5 lines)
Chart speed
Date/time: Year, month, date, time, minute, second (date format depends on the date printout/
display format)
Printout On/Off selection: Batch name, chart speed, and date/time
Message printouts
In the 5 message formats, measured values*, strings (up to 16 characters), and date/time can be
arbitrarily combined and printed out (up to 69 characters total).
* Computed values can also be included on models with the /M1 option.
12.5 Specfcatons of Optonal Functons