beautypg.com

Explanaton – Yokogawa µR20000 User Manual

Page 197

background image

IM 04P02B01-01E

9-14

Explanaton

Tmer No.

There are three timers.
Periodic: The timer for determining the periodic printout interval. The computed result is

printed every interval, and the computed TLOG value is reset.

1:

The timer of timer No. 1. Specify whether the computed value is printed every
interval and whether to reset the computed value.

2:

The timer of timer No. 2. Specify whether the computed value is printed every
interval and whether to reset the computed value.

• Tmer operaton

The table below shows how each timer operates.

Item

Tmer #

Perodc

1 and 2*

Application

Periodic

TLOG computation

Target channel

Measurement and

computation channels

Computation channels

Timer mode**

Absolute time mode

Absolute or relative time mode

Reset computed TLOG value

Yes

Yes/No selectable

Print when computation stops

No

Yes

* For the timer 1 and 2 settings, see section 9.12.
** Absolute time mode: Keeps time from the reference time.
Relative time mode: Starts the time in sync with the starting of the computation.

SUM scale

Set the sum scale when using statistical calculation (TLOG.SUM).
For the definition of the term “sum scale,” see page 7-14.
Off: Simply sums the computed values.
/s: Sums by converting the computed values to a value over 1 second.
/min: Sums by converting the computed values to a value over 1 minute.
/h: Sums by converting the computed values to a value over 1 hour.
/day: Sums by converting the computed values to a value over 1 day.

Setting the periodic printout timer: Section 7.8

Setting Timer 1 and Timer 2: Section 9.12

9.6 Specfyng the Tmer Used n Statstcal Calculatons (TLOG)