12-15
IM 04P02B01-01E
Spec
fcat
ons
1
2
3
4
5
6
7
8
9
10
11
12
App
Index
Item
Specfcatons
Alarms
Number of alarms
Up to four alarms (level) for each measurement channels.
Alarm types
High limit (H), low limit (L), delay high limit (T), delay low limit (t). The alarm symbol is shown in
parentheses.
Alarm delay time of delay high and low limit alarms (can be set for each channel, common within a
channel) See section 12.2
Hysteresis
Applied to high limit alarm and low limit alarm.
Hysteresis range: Approx. 0.0% to 1.0% of the recording span (0.1% steps)
Miscellaneous
See section 12.2.
Display
See section 12.4.
Cu10, Cu25 RTD Input (/N1)
Item
Specfcatons
Cu10, Cu25 RTD
This option allows Cu10 and Cu25 inputs to be added to the standard input types.
Input type and measurable range
Input Type
Measurable Range
RTD
(Measurement current
i: 2 mA)
Cu10 (GE)
–200.0 to 300.0°C
–328.0 to 572.0°F
Cu10 (L&N)
Cu10 (WEED)
Cu10 (BAILEY)
Cu10: α = 0.00392 at 20°C
Cu10: α = 0.00393 at 20°C
Cu25*: α = 0.00425 at 0°C
* Measurement current i = 1 mA
Measurement and recording accuracy
Input Type
Measurement Accuracy
Recordng Accuracy
Cu10 (GE)
Cu10 (L&N)
Cu10 (WEED)
Cu10 (BAILEY)
Cu10: α = 0.00392 at 20°C
Cu10: α = 0.00393 at 20°C
±(0.4% of rdg + 1.0°C)
Measurement accuracy
±(0.3% of recording span)
Cu25: α = 0.00425 at 0°C
±(0.3% of rdg + 0.8°C)
3 Legs Isolated RTD (/N2)
Item
Specfcatons
Input terminal isolation
Applies to the dot model.
The RTD input terminals are isolated between channels (on the standard dot model, input
terminal b are common to all channels)
Expanson Inputs (/N3)
Item
Specfcatons
Input type and measurable range
Adds the input types shown in the table below.
Input Type
Measurable Range
Thermocouple
PR40-20
0.0 to 1900.0°C
32 to 3452°F
PLATINEL
0.0 to 1400.0°C
32 to 2552°F
NiNiMo
0.0 to 1310.0°C
32 to 2390°F
W/WRe26
0.0 to 2400.0°C
32 to 4352°F
Type N (AWG14)
0.0 to 1300.0°C
32 to 2372°F
Kp vs Au7Fe
0.0 to 300.0 K
RTD
(Measuring current
i = 1 mA)
Pt25
–200.0 to 550.0°C
–328.0 to 1022.0°F
Pt50
–200.0 to 600.0°C
–328.0 to 1112.0°F
Ni100 (SAMA)
–200.0 to 250.0°C
–328.0 to 482.0°F
Ni100 (DIN)
–60.0 to 180.0°C
–76.0 to 356.0°F
Ni120
–70.0 to 200.0°C
–94.0 to 392.0°F
J263*B
0.0 to 300.0 K
Cu53
–50.0 to 150.0°C
–58.0 to 302.0°F
Cu100: α = 0.00425 at 0°C
–50.0 to 150.0°C
–58.0 to 302.0°F
12.5 Specfcatons of Optonal Functons