Yokogawa µR20000 User Manual
Page 100
IM 04P02B01-01E
4-12
4.3 Menu Structure, Settngs, and Lst of Default Values
Setup Item
Pen/Dot
Selectable Range or Selectons
Default Value
Partial > Partial
-
Not/Use
Not
Language > Lang
-
English/Japanese/German/French
English
Date format > Type
-
Y/M/D M/D/Y D/M/Y D.M.Y M.D.Y
M.D.Y
Temperature > Temp
-
°C/°F
°C
Personalize > Add function > Bias
-
Not/Use
Not
Personalize > Add function > SQRT low-cut -
Not/Use
Use
Personalize > Add function > 1-5V low-cut -
Not/Use
Not
Personalize > Add function > Alarm delay -
Not/Use
Not
Personalize > Add function > Calibration
-
Not/Use
Use
Personalize > Time print > Alarm
-
HH:MM, HH:MM:SS, M/D H:M, M/D H:M:S,
YMD H:M:S
HH:MM
Personalize > Time print > Message
-
HH:MM, HH:MM:SS, M/D H:M, M/D H:M:S,
YMD H:M:S, None
HH:MM
Personalize > Time print > RCD On
-
HH:MM, HH:MM:SS, M/D H:M, M/D H:M:S,
YMD H:M:S
HH:MM
Personalize > Time print > C.Speed
-
HH:MM, HH:MM:SS, M/D H:M, M/D H:M:S,
YMD H:M:S
HH:MM
Setting initialization
Initialize > Mode
-
Setup+Set/Set
Setup+Set
Initialize > Mode > Are you sure?
-
No/Yes
No
Remote (/R1 option)
Remote > Remote number
-
1/2/3/4/5
1
Remote > No.
-
Record On Off /Chart speed/Time adjust/
Math start stop (/M1)/Math reset (/M1)/
Manual print/Alarm ACK/Message1/Message2/
Message3/Message4/Message5/
Priority R_RCD (/BT1)/BatchCMT switch (/BT1)/
None
(/M1, /BT1: option)
Record On/Off
Math (/M1 option)
Math > Timer (TLOG) > Timer number
-
1/2
1
Math > Timer (TLOG) > Mode
-
Off/Relative/Absolute
Absolute
Math > Timer (TLOG) > Interval (Relative) -
10 min to 24 h (1 min steps)
01:00
Math > Timer (TLOG) > Interval (Absolute) -
10min/12min/15min/20min/30min/1h/2h/3h/4h/6h/
8h/12h/24h
1h
Math > Timer (TLOG) > Ref. Time
-
Hour 0 to 23 (1 hour steps)
00:00
Math > Timer (TLOG) > Reset
-
On/Off
On
Math > Timer (TLOG) > Print
-
On/Off
On
Math > Color > Channel
Dot Model 0A/0B/0C/0D/0E/0F/0G/0J/0K/0M/0N/0P/
1A/1B/1C/1D/1E/1F/1G/1J/1K/1M/1N/1P
0A
Math > Color > Color
Dot Model Purple/Red/Green/Blue/Brown/Black
Purple: 0A/0G/1A/1G
Red: 0B/0J/1B/1J
Green: 0C/0K/1C/1K
Blue: 0D/0M/1D/1M
Brown: 0E/0N/1E/1N
Black: 0F/0P/1F/1P
Math > Output pen > Pen ← CH
Pen Model Pen: 1 to 4, Channel: 01 to 04/0A to 0J
1pen: 01, 2pen: 02,
3pen: 03, 4pen: 04
Math > Print2 > CH
-
0A/0B/0C/0D/0E/0F/0G/0J/0K/0M/0N/0P/
1A/1B/1C/1D/1E/1F/1G/1J/1K/1M/1N/1P
0A
Math > Print2 > Mode
-
AVE/MIX/SUM/MIN/MAX/INST
AVE
Math > Print2 > SUM scale
-
Off, /s, /min, /h, /day
Off
Math > Bar graph > CH
-
0A/0B/0C/0D/0E/0F/0G/0J/0K/0M/0N/0P/
1A/1B/1C/1D/1E/1F/1G/1J/1K/1M/1N/1P
0A
Math > Bar graph > Graph
-
Normal/Center
Normal
Math > Error data > Error
-
+Over/–Over
+Over
Math > Error data > Over
-
Skip/Limit
Skip
RS-422/485 (/C3 option)
RS-422/485 > Address
-
1 to 32
1
RS-422/485 > Baud rate
-
1200/2400/4800/9600/19200/38400
9600
RS-422/485 > Data length
-
7/8
8
RS-422/485 > parity
-
Odd/Even/None
Even
RS-422/485 > Protocol
-
NORMAL/MODBUS
NORMAL