beautypg.com

Remote control 5 ponts (/r1), Portable type (/h5x) – Yokogawa µR20000 User Manual

Page 244

background image

IM 04P02B01-01E

12-16

Item

Specfcatons

Measurement and recording accuracy

Input Type

Measurement Accuracy Recordng Accuracy

PR40-20

0 to 450°C

450 to 750°C

750 to 1100°C

1100 to 1900°C

Not warranted

±(0.9% of rdg + 3.2°C)

±(0.9% of rdg + 1.3°C)

±(0.9% of rdg + 0.4°C)

Measurement
accuracy
±(0.3% of
recording span)

PLATINEL

±(0.25% of rdg + 2.3°C)

NiNiMo

±(0.25% of rdg + 0.7°C)

W/WRe26

0 to 400°C

400 to 2400°C

±15.0°C or less

±(0.2% of rdg + 2.0°C)

Type N (AWG14)

±(0.2% of rdg + 1.3°C)

Kp vs Au7Fe

0 to 20 K

20 to 300 K

±4.5 K

±2.5 K

Pt25

±(0.15% of rdg + 0.6°C)

Pt50

±(0.3% of rdg + 0.6°C)

Ni100 (SAMA)

±(0.15% of rdg + 0.4°C)

Ni100 (DIN)
Ni120
J263*B

0 to 40 K

40 to 300 K

±3.0 K

±1.0 K

Cu53

±(0.15% of rdg + 0.8°C)

Cu100

±(0.2% of rdg + 1.0°C)

Note) No RJC for PR40-20 (fixed to 0°C)

Remote Control 5 Ponts (/R1)

Item

Specfcatons

Number of input terminals 5
Input type

Isolated from the main circuitry through a photocoupler, built-in isolated power supply for the input

terminals, and shared common

Input type and signal level

Voltage-free contact

Contact closed at 200 Ω or less and contact open at 100 kΩ or greater

Open collector

ON voltage: 0.5 V or less (sink current 30 mA or more), leakage current when OFF: 0.25 mA or less

Signal type

Edge, level, or trigger (250 ms or more)

Operation

Perform the following control operations by applying a given signal to the remote signal input

terminal.
• Start/stop recording (edge)
• Alarm ACK (trigger)
• Set the clock (adjust the clock to the nearest hour with the contact input, trigger)
Tme When Sgnal Is Input Procedure

00 min 00 s to 01 min 59 s

Truncates the minutes and seconds.Example: 10:00:50 → 10:00:00

58 min 00 s to 59 min 59 s

Rounds up the minutes and seconds.Example: 10:59:50 → 11:00:00

02 min 00 s to 57 min to 59 s No operation

• Manual printout (trigger)
• Message 1 to 5 printout (trigger)
• Switch the chart speed (level)
• Start/stop computation (/M1 option) (edge)
• Reset computation (/M1 option) (trigger)
• Priority to remote recording (/BT1 option) (edge)
• Batch comment switching (/BT1 option) (level)

Portable Type (/H5x)

Item

Specfcatons

Installation

Desktop type (with a carrying handle)

External dimensions

288 (W) × 329.7 (H) × 292 (D) mm (including the handle and feet)

Weight

Add 1.7 kg to the weight given in General Specifications (see section 12.6, excluding the power

cord)

Standard accessories*

With a power cord

* Panel mounting brackets are not included.

12.5 Specfcatons of Optonal Functons