App index, Alarm functons, Recordng functons – Yokogawa µR20000 User Manual
Page 51
1-35
IM 04P02B01-01E
Funct
onal
Explanat
on
and
Setup
Gu
de
1.10 Functon Setup Gude
1
2
3
4
5
6
7
8
9
10
11
12
App
Index
Item
Descrpton
Reference
Secton
Moving average (dot model)
Use
Movng_AVE in Basic Setting mode and select Use or Not.
7.11
If Use is selected, set the number of samples of moving average using
Aux >
Movng_AVE in Setting mode.
6.3
If Not is selected, the
Aux > Movng_AVE item does not appear.
Integration time of the A/D converter
7.2
Use
A/D in Basic Setting mode to set the integration time of the A/D converter.
Temperature Unit
Select the temperature unit using
Temperature in Basic Setting mode.
7.25
Alarm functons
Item
Descrpton
Reference
Secton
Alarms for each channel
Use
Alarm in Setting mode.
5.2
Delay high limit alarm/delay low limit alarm
• Alarm type
7.15
Use
Personalze > Add functon > Alarm delay in Basic Mode and select Use or
Not.
If Use is selected, delay high limit alarm (T) and delay low limit alarm (t) become
selectable under
Alarm > Type in Setting mode.
5.2
If Not is selected, alarm delay cannot be selected.
• Alarm delay time
6.10
Use
Aux > Alarm delay tme in Setting mode to set the alarm delay time.
High limit on rate-of-change alarm/low limit on rate-of-change alarm
Use
Alarm in Setting mode and set the channel to rate-of-change alarm.
5.2
Use
Alarm > Increase in Basic Setting mode to set the interval of the high limit on
rate-of-change alarm; use
Alarm > Decrease in Basic Setting mode to set the interval
of the low limit on rate-of-change alarm.
7.1
Use the alarm ACK operation
• Relay operation and display operation
7.1
Set
Alarm > Behavor in Basic Setting mode to Hold and set Alarm > Indcator to
Hold.
• Executing the alarm ACK operation
3.12
Use
Func > Alarm ACK in Operation mode to execute the release of the alarm
output.
Set a hysteresis on the alarm occurrence/release value of high limit alarm and low limit alarm
Use
Alarm > Hysteress in Basic Setting mode to set the hysteresis to be applied to
the high limit alarm and low limit alarm of measurement channels.
7.1
Likewise, use
Alarm > Math Hysteress to set the hysteresis to be applied to the high
limit alarm and low limit alarm of computation channels (/M1 option).
Change the alarm output relay operation
If
Alarm > Act in Basic Setting mode set to De_energize, alarm output relay is
energized during normal operation and de-energized when an alarm occurs.
7.1
Diagnosis output
Use
Alarm > Dagnoss in Basic Setting mode to set the function.
7.1
Recordng functons
Item
Descrpton
Reference
Secton
Chart speed
Use
Chart in Setting mode to set the chart speed.
5.4
Turn trend recording ON/OFF (dot model)
Use
Aux > Prnt out in Setting mode to set whether to trend record on each
measurement channel.
6.6
Change the recording color of measurement channels (dot model).
Use
Color in Basic Setting mode to set the recording color of measurement channels. 7.5
Record by compensating for the pen offset along the time axis (pen model)
Use
Aux > POC in Setting mode to turn On/Off offset compensation.
7.6
Record by setting recording zone
Use
Aux > Zone in Setting mode to set the recording zone for each channel.
6.4
Partial expanded recording Use
Partal in Basic Setting mode and select Use or Not.
7.13
If Use is selected, set the display mode using
Aux > Partal in Setting mode.
6.5
If Not is selected, the
Aux > Partal item does not appear.