IAI America XSEL-KE User Manual
Page 37
22
Part 1 Installation
(2) Type K (General-purpose type)
Type
Type K (General-purpose type)
Number of controlled axes
1 axis
2 axes
3 axes
4 axes
Total output when maximum
number of axes are connected
Power-source voltage 100 V: 800 W
Power-source voltage 200 V: 1600 W
Power-source voltage
Single-phase, 100 to 115/200 to 230 VAC (factory setting)
Operating power-source
voltage range
r10%
Power-source frequency
50 Hz/60 Hz
Isolation resistance
10 M
: min. (measured at 500 VDC between the power terminal and I/O
terminals and between the external terminals (together) and case)
Withstand voltage
1500 VAC for 1 minute (Note)
Surrounding air temperature
range
0
qC to 40qC
Surrounding humidity range
30% to 85%
Storage temperature range
-10
qC to 65qC
Axis control method
AC full digital servo
Position detection methods
17-bit incremental encoder (wire-saving type)
17-bit rotation data backup absolute encoder (wire-saving type)
(Both have a control resolution of 14 bits)
Batteries
For backup of absolute data: IA-XAB-BT by IAI
For backup of system memory: CR2032
Speed setting
1 mm/sec to 2000 mm/sec
Acceleration/deceleration
setting
0.01 G to 1 G
Programming language
Super SEL language
Program steps
6000 steps (total)
Number of positions
3000 positions (total)
Number of programs
64 programs
Multi-tasking 16
programs
Storage device
Flash ROM + SRAM battery backup
Data input methods
Teaching pendant or PC software
Standard inputs
32 points (total of dedicated inputs + general-purpose inputs)
Standard outputs
16 points (total of dedicated outputs + general-purpose outputs)
Expanded inputs/outputs
48 points per unit (a maximum of 3 units can be added)
Serial communication
For connection of teaching pendant or PC
Other inputs/output
Emergency-stop input, safety-gate input, system ready output
Protective functions
Motor overcurrent, overload, motor-driver temperature check, overload
check, encoder-open detection, soft limit over, system error, battery error
Drive-source cutoff method
Relay
Regenerative resistance
Built-in (220
:, 80 W); external regenerative resistance supported
Accessory
I/O flat cable
Optional parts and
components
Teaching pendant, PC software, absolute-data backup battery unit, I/O
shield cable, I/O expansion board
Note: The withstand voltage of the actuator motor is 1000 V for 1 minute.
When performing a withstand voltage test with the controller and actuator connected, make sure the test voltage and
duration will not exceed 1000 V and 1 minute, respectively.
, Type KE (CE-compliant)