251
Part 4 Commands
Schematic diagram of placement-point positions based on the above program
x The number shown at the top right of each circle indicates a palletizing position number.
x Count in PX-axis direction = 5, Count in PY-axis direction = 7
x Zigzag offset: 20
x Zigzag count: 4
x Pallet shift angle T±q
Axis-1 direction
End-point coordinates of preferential axis (PX-axis): Position No. 2 (260, 105, 100)
Reference point: Position No. 1
(100, 100, 100)
PY-axis
End-point coordinates of PY-axis: Position No. 3
PX-axis
Axis-2 direction
T
5
4
3
2
1
20
14
23
32
27
13
22
31
17
26
12
21
30
7
16
25
11
6
15
24
10