IAI America XSEL-KE User Manual
Page 344
![background image](/manuals/350328/344/background.png)
329
Appendix
I/O Parameters
No. Parameter
name
Default value
(Reference)
Input range
Unit
Remarks
12 Expanded I/O2 error
monitor (I/O3)
1
0 ~ 5
0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to
24-V I/O power source)
(Main application version 0.55 or later)
3: Monitor (Monitor only errors relating to 24-V
I/O power source)
(Main application version 0.55 or later)
* Some exceptions apply.
13 Expanded I/O3 error
monitor (I/O4)
1
0 ~ 5
0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to
24-V I/O power source)
(Main application version 0.55 or later)
3: Monitor (Monitor only errors relating to 24-V
I/O power source)
(Main application version 0.55 or later)
* Some exceptions apply.
14 Number of ports
using network-I/F-
card remote input
0
0 ~ 256
Refer to the operation manual for each
network I/F card (CC-Link, DeviceNet, etc.).
15 Number of ports
using network-I/F-
card remote output
0
0 ~ 256
Refer to the operation manual for each
network I/F card (CC-Link, DeviceNet, etc.).
16 (For future expansion
= Change prohibited)
0
0 ~ 256
Multiple of 8
17 (For future expansion
= Change prohibited)
0
0 ~ 256
Multiple of 8
18~
19
(For expansion)
0
20 Input filtering periods
2
1 ~ 9
msec Input signal is recognized when the status is
held for twice the period set by this parameter.
21 Register input filtering
periods
2
1 ~ 9
msec Input signal is recognized when the status is
held for twice the period set by this parameter.
22 Remote-I/O-card
fieldbus ready
timeout value
a
PVHF 7LPHRXWFKHFNLVQRWSHUIRUPHGLI³´LVVHW
23 Overcurrent/power-
supply error detection
input specification for
multi-point DIO
external terminal
block
0H 0H
~
FFFFFFFFH
Bits 0 to 3:
For future expansion
Bits 4 to 7:
Expanded I/O1 (I/O2) input
specification
Bits 8 to 11:
Expanded I/O2 (I/O3) input
specification
Bits 12 to 15: Expanded I/O3 (I/O4) input
specification
(0: Do not use error detection input
1: Use error detection input = IN023 on card
2: Use error detection input = IN047 on card
3: Use error detection input = IN023/47 on card)
* Determine an appropriate setting after
checking the specification of the multi-point
DIO terminal block unit to be connected.
* The input port used for the error detection
input cannot be used as a general-purpose
input port.
* If the main application version is 0.82 or
HDUOLHUEHVXUHWRVSHFLI\³'RQRWXVH
HUURUGHWHFWLRQLQSXW´