beautypg.com

IAI America XSEL-KE User Manual

Page 351

background image

336

Appendix

I/O Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

115 SIO

system

reserve

(SP9)

0

0H ~

FFFFFFFFH

116~1

19

(For expansion)

0

120

Network attribute 1

1

0H ~

FFFFFFFFH

Bits 0 to 3:

CC-Link remote register area
H/L byte swap selection (0: Do not
swap, 1: Swap)
* The number of used ports and

number of occupied stations in I/O
parameter Nos. 14 and 15 must
match.

(Main application version 0.55 or
later)

121

Network attribute 2

0

0H ~

FFFFFFFFH

122

Network attribute 3

0

0H ~

FFFFFFFFH

123

Network attribute 4

0

0H ~

FFFFFFFFH

Bits 0 to 3:

Ethernet TCP/IP message
communication
Selection whether to permit 0.0.0.0
(IP address of connection destination
can be ignored) as IP address of
connection destination on server
(0: Do not permit

1: Permit (not recommended))

* Note: Number of clients that can

be connected simultaneously to
one server port channel = 1

124

Network attribute 5

0

0H ~

FFFFFFFFH

Ethernet TCP/IP message communication attribute

Ethernet client/server type
(0: Not in use

1: Client (Automatic assignment of own port

number)

(2: Client (Specification of own port number)

o This setting is not recommended because

of device limitations, such as an error
generation when the port is opened for
approx. 10 minutes after disablement of
close response check due to a power failure
at the connection destination, etc.)

3: Server (Specification of own port number))

* Note: Number of clients that can be

connected simultaneously to one
server port channel = 1

Bits 0 to 3:

IAI protocol B/TCP (MANU mode)

* PC software can be connected only in the case of

a client.

Bits 4 to 7:

IAI protocol B/TCP (AUTO mode)

* PC software can be connected only in the case of

a client.

Bits 8 to 11:

Channel 31 opened to user

Bits 12 to 15:

Channel 32 opened to user

Bits 16 to 19:

Channel 33 opened to user

Bits 20 to 23:

Channel 34 opened to user

* If the parameter settings for own port number,

client/server type, IP address of connection
destination and port number of connection
destination do not match completely between the
IAI protocol B/TCP MANU and AUTO modes, the
connection will be cut off when the MANU/AUTO
mode is switched.

PC: PC software
TP: Teaching pendant