3 interface specifications – IAI America PCON-CFA User Manual
Page 93
3. PCON-CA/CF
A
87
3.3 Interface
Specifications
Item Specification
DeviceNet 2.0
Group 2 only server
Communication protocol
Network-powered isolation node
Bit strobe
Communication specification
Master-slave connection
Polling
Baud rate
Automatically set to the same value as the band rate set in the master
Baud rate
Maximum network length
Maximum branch
line length
Total branch
line length
500 kbps
100 m
39 m
250 kbps
250 m
78 m
125 kbps
500 m
6 m
156 m
Communication cable length
Note) When a large-size DeviceNet cable is used.
Communication power supply
24 VDC (supplied from DeviceNet)
Consumption current of
communication power supply
60 mA
Number of occupied nodes
1 node
Connector
MSTBA2.5/5-G-5.08AU M (*1) by Phoenix Contact
(*1) The cable-end connector is a standard accessory.
SMSTB2.5/5-ST-5.08AU by Phoenix Contact