background image

4. SCON-CA


174

4.7.3 Position/Simple Direct Mode (Number of Occupied Channels: 4)

In this mode, the actuator is operated by specifying position numbers. You can switch the control signal (PMOD)
to select whether to specify the target position directly and numerically or by using a value registered in the
position data table.
Data other than the target position, such as speed, acceleration/deceleration and positioning band, are set using
values in the position table stored in the controller. Set position data by referring to the operation manual for the
controller.
Up to 768 sets of positioning data can be specified.
The key ROBO Cylinder functions that can be controlled in this mode are summarized in the table below.

Actuator function

{: Direct control

U: Indirect control

X: Invalid

Remarks

Home-return operation

{

Positioning operation

{

Speed and acceleration/deceleration setting

U

Pitch feed (inching)

U

Push-motion operation

U

Speed change during movement

U

Operation at different acceleration and deceleration

U

These items must be
set in the position data
table.

Pause

{

Zone signal output

U

Zones are set using
position data or
parameters.

PIO pattern selection

X


(1) PLC channel configuration (* n indicates the node address of each axis.)

Parameter No.

84

SCON-CA input

register

PLC output channel

SCON-CA output

register

PLC input channel

n+0 n+0

Target position

n+1

Current position

n+1

Specified position

number

n+2

Completed position

number (simple

alarm code)

n+2

1

Control signal

n+3

Status signal

n+3

(Note) Exercise caution to avoid node address duplication.