beautypg.com

Caution – IAI America PCON-CFA User Manual

Page 154

background image

3. PCON-CA/CF

A


148

Speed n2

Speed n3

[1]

[2]

[3]

(4) Data change during movement

In the half direct mode or full direct mode, the value currently set to a given channel among the channels for target
position data, acceleration/deceleration data, speed data, positioning band and push-motion current-limiting value,
can be changed while the actuator is moving.
After a desired data has been changed, keep the positioning command (DSTR) signal “ON” for at least tdpf.
Also make sure that after the DSTR is turned “OFF,” the signal will not be turned “ON” again until at least a time
corresponding to “twcsON + twcsOFF” elapses.
An example of changing the speed or acceleration/deceleration is shown in the figure below.



































1. If the speed is not set or “0” speed is set, the actuator will remain stationary and no alarm will

generate.

2. If the speed is changed to “0” while the actuator is moving, the actuator will decelerate to a stop and

no alarm will generate.

3. Even when the acceleration/deceleration or speed data alone is changed while the actuator is

moving, the target position data must also be set.

4. Even when the target position alone is changed while the actuator is moving, the

acceleration/deceleration and speed data must also be set.

Caution

Set value of speed or

acceleration/deceleration

(PLCĺPCON)

DSTR

(PLCĺPCON)

PEND

(PCONĺPLC)

MOVE

(PCONĺPLC)

Actuator speed

This manual is related to the following products: