IAI America PCON-CFA User Manual
Page 179
4. SCON-CA
173
Setting of Parameter No. 25
Force control mode 1
Force control mode 2
6 7
Category
Port
No.
Symbol
Signal name
Symbol
Signal name
0 PC1
ST0 Start
position
0
1 PC2
ST1 Start
position
1
2 PC4
ST2 Start
position
2
3 PC8
ST3 Start
position
3
4 PC16
Command position
number
ST4 Start
position
4
5 -
-
6 -
-
7 -
Not available.
-
Not available
8 CLBR
Load cell calibration
command
CLBR
Load cell calibration
command
9 BKRL
Forced brake
release
BKRT
Forced brake
release
10
RMOD
Operation mode
RMOD
Operation mode
11
HOME
Home return
HOME
Home return
12 *STP
Pause
*STP
Pause
13
CSTR
Positioning start
-
Not available.
14 RES
Reset
RES
Reset
PLC
output
o
SCON-CA
input
15
SON
Servo ON command
SON
Servo ON command
0
PM1
PE0
Position 0 complete
1
PM2
PE1
Position 1 complete
2
PM4
PE2
Position 2 complete
3
PM8
PE3
Position 3 complete
4 PM16
Completed position
number
PE4
Position 4 complete
5
TRQS
Torque level status
TRQS
Torque level status
6 LOAD
Load output
judgment
LOAD
Load output
judgment
7 CEND
Load cell calibration
complete
CEND
Load cell calibration
complete
8
PZONE
ZONE1
Position zone/
Zone 1
PZONE
ZONE1
Position zone/
Zone 1
9 RMDS
Operation mode
status
RMDS
Operation mode
status
10 HEND
Home return
complete
HEND
Home return
complete
11 PEND
Position complete
signal
PEND
Position complete
signal
12 SV
Ready
SV
Ready
13
*EMGS
Emergency stop
*EMGS
Emergency stop
14 *ALM
Alarm
*ALM
Alarm
SCON-CA
output
o
PLC input
15 *BALM
Battery alarm
*BALM
Battery alarm
The signals indicated by * are ON in a normal state.
The signals denoted by “Not available” are not controlled (their ON/OFF status is indeterminable).