4. SCON-CA


196


(* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)

Signal type

Bits

Symbol

Description

Details

b15 EMGS

Emergency stop: An emergency stop is being executed when
the signal is ON.

4.7.11 (2)

b14 PWR

Controller ready: The signal turns ON when the controller
becomes ready.

4.7.11 (1)

b13 ZONE2

Zone 2: The signal is ON when the current position is inside the
specified zone.

4.7.11 (12)

b12 ZONE1

Zone 1: The signal is ON when the current position is inside the
specified zone.

4.7.11 (12)

b11 PZONE

Position zone: The signal is ON when the current position is
inside the specified position zone.

4.7.11 (12)

b10 MODES

Teaching mode signal: The signal is ON when the teaching
mode is selected.

4.7.11 (26)

b9 WEND

Position data read complete: The signal turns ON when the
position data read is complete.

4.7.11 (27)

b8 RMDS

Operation mode: The signal is OFF when the current mode
AUTO, or ON when the current mode is MANU.

4.7.11 (19)

b7 BALM

Absolute battery voltage low warning: This signal turns ON when
the voltage drops.

4.7.11 (6)

b6

-

Not available

4.7.11 (25)

b5 PSFL

Missed load during push-motion operation: The signal turns ON
when the actuator missed the load during push-motion
operation.

4.7.11 (23)

b4

SV

Ready: The signal is ON when the servo is ON.

4.7.11 (5)

b3

ALM

Alarm: The signal turns ON when an alarm occurs.

4.7.11 (3)

b2

MOVE

Moving signal: The signal is ON while the actuator is moving.

4.7.11 (9)

b1 HEND

Home return complete: The signal turns ON when the home
return is completed.

4.7.11 (6)

PLC in

put

Status

signal 2

b0 PEND

Positioning complete signal: The signal turns ON when the
positioning is completed.

4.7.11 (10)