beautypg.com

IAI America PCON-CFA User Manual

Page 164

background image

4. SCON-CA


158

Communication
cable

Flat cable

Target position: 100.00 mm
Positioning band: 0.10 mm
Speed specification:
100.0 mm/sec
Acceleration: 0.30 G
Deceleration: 0.30 G
Push current: 50%
Load current threshold: 0
Zone+: 50.00 mm
Zone-: 30.00 mm

SCON-CA supporting
PROFIBUS-DP

Actuator


[4] Full direct mode: In this mode, the actuator is operated by specifying all values relating to position control

(target position, speed, acceleration/deceleration, etc.) directly as values.
Number of occupied channels: 16CH

















[5] Remote I/O mode 2: In this mode, the actuator is operated by PIOs (24-V I/Os) via DeviceNet

communication.
The current-position and command-current read functions are available in addition to
the functions provided in mode [1].
Number of occupied channels: 6CH












[6] Position/simple direct mode 2: In this mode, the actuator is operated by specifying position numbers.

In this mode, the force control function is available instead of the teaching
function and zone function available in mode [2].

Number of occupied channels: 4CH











SCON-CA not supporting

DeviceNet

SCON-CA supporting

DeviceNet

DeviceNet connection

PIO connection

Target position: 100.00 mm

+

Position No. 0

SCON-CA supporting

DeviceNet

Actuator

Speed

Acceleration Deceleration

Push

This manual is related to the following products: