4. SCON-CA


182


PLC input
Channel (* n indicates the node address of each axis.)



















































1 word (channel) = 16 bits

Current
position (lower
word)

Current
position (upper
word)

Status signal

If the current position is a negative value, it is indicated by a 2’s complement.

Command
current (lower
word)

Command
current (upper
word)

Current speed
(lower word)

Current speed
(upper word)


Alarm code

If the current speed is a negative value, it is indicated by a 2’s complement.