3. PCON-CA/CF

A


117


(* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)

Address Bits

Symbol

Function

Details

b2 DIR

Push direction specification:
When this signal is OFF, push-motion operation is performed in
the direction of the position determined by subtracting the
positioning band from the target position.
When the signal is ON, push-motion operation is performed in
the direction of the position determined by adding the positioning
band to the target position.

3.7.7 (22)

b1 PUSH

Push-motion specification: Positioning operation is performed
when this signal is OFF, and push-motion operation is performed
when the signal is ON.

3.7.7 (21)

Control

signal 1

b0 -

Not

available.

-

b15 BKRL

Forced brake release: The brake is released when this signal
turns ON.

3.7.7 (18)

b14 RMOD

Operation mode: The AUTO mode is selected when this signal is
OFF, and the MANU mode is selected when the signal is ON.

3.7.7 (19)

b13
b12
b11
b10

b9

- Not

available.

-

b8 JOG+

+Jog: The actuator moves in the direction opposite home when
this signal is ON.

3.7.7 (13)

b7 JOG-

-Jog: The actuator moves in the direction of home when this
signal is ON.

3.7.7 (13)

b6 JVEL

Jog-speed/inch-distance switching: The values set in parameter
No. 26, “Jog speed” and parameter No. 48, “Inch distance” are
used when this signal is OFF, and the values set in parameter
No. 47, “Jog speed 2” and parameter No. 49, “Inch distance 2”
are used when the signal is ON.

3.7.7 (14)

b5 JISL

Jog/inch switching: Jog operation is performed when this signal
is OFF, and inch operation is performed when the signal is ON.

3.7.7 (15)

b4 SON

Servo ON command: The servo turns ON when this signal turns
ON.

3.7.7 (5)

b3

RES

Reset: A reset is performed when this signal turns ON.

3.7.7 (4)

b2

STP

Pause: A pause command is issued when this signal turns ON.

3.7.7 (11)

b1 HOME

Home return: A home-return command is issued when this signal
turns ON.

3.7.7 (6)

PLC output

Control

signal 2

b0 DSTR

Positioning start: A move command is issued when this signal
turns ON.

3.7.7 (8)