IAI America PCON-CFA User Manual
Page 52
2. ACON-C/CG,
PCON-C/CG
46
(* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)
Signal type
Bits
Symbol
Description
Details
Current
position
32-bit data
-
32-bit signed integer indicating the current position.
The setting unit is 0.01 mm.
(Example) Reading: 000003FF
H
= 1023 (decimal)
= 10.23 mm
* If current positions are read as hexadecimals, negative values
are indicated by 2’s complements.
2.9 (3)
Command
current
32-bit data
-
32-bit integer.
The electrical current presently specified by a command is
indicated.
The setting unit is mA.
(Example) Reading: 000003FF
H
= 1023 (decimal)
= 1023 mA
2.9 (3)
Current
speed
32-bit data
-
32-bit integer.
The current speed is indicated.
The setting unit is 0.01 mm/sec.
(Example) Reading: 000003FF
H
= 1023 (decimal)
= 10.23 mm/sec
2.9 (3)
Alarm
code
16-bit data
-
16-bit integer.
If an alarm occurred, a corresponding alarm code is output.
If no alarm is present, “0” is set.
For details on alarms, refer to the operation manual for the
controller.
2.9 (3)
b15 EMGS
Emergency stop: An emergency stop is actuated when this
signal turns ON.
2.7.7 (2)
b14 PWR
Controller ready: This signal turns ON when the controller
becomes ready.
2.7.7 (1)
b13 ZONE2
Zone 2: This signal turns ON when the current position is inside
the specified zone.
2.7.7 (12)
b12 ZONE1
Zone 1: This signal turns ON when the current position is inside
the specified zone.
2.7.7 (12)
b11 PZONE
Position zone: This signal turns on when the current position is
inside the position zone.
2.7.7 (12)
ACON -
Not available (ON/OFF status is indeterminable).
-
b10
PCON LOAD
Load output judgment:
When this signal is ON, the specified load has been reached.
When the signal is OFF, the load has not been reached yet.
(For details, refer to the operation manual for the controller.)
2.7.7 (26)
ACON -
Not available (ON/OFF status is indeterminable).
-
b9
PCON TRQS
Torque level: When this signal is ON, the specified torque has
been reached. When the signal is OFF, the torque has not been
reached yet.
(For details, refer to the operation manual for the controller.)
2.7.7 (27)
b8 RMDS
Operation mode status: This signal is OFF when the current
mode is AUTO, or ON when the mode is MANU.
2.7.7 (19)
b7 GHMS
Home return in progress: This signal remains ON while home
return is in progress.
2.7.7 (6)
b6 PUSHS
Push motion in progress: This signal remains ON while
push-motion operation is in progress.
2.7.7 (25)
b5 PSFL
Load missed in push motion: This signal turns ON when the
actuator missed the load in push-motion operation.
2.7.7 (23)
b4
SV
Ready: This signal turns ON when the servo turns ON.
2.7.7 (5)
b3
ALM
Alarm: This signal turns ON when an alarm occurs.
2.7.7 (3)
b2 MOVE
Moving signal: This signal remains ON while the actuator is
moving.
2.7.7 (9)
b1 HEND
Home return complete: This signal turns ON when home return
is completed.
2.7.7 (6)
PLC in
put
Status
signal
b0 PEND
Position complete signal: This signal turns ON when positioning
is completed.
2.7.7 (10)