2. ACON-C/CG,

PCON-C/CG


30


(* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)

Signal type

Bits

Symbol

Description

Details

Current

position

32 bits

-

32-bit signed integer indicating the current position.
The setting unit is 0.01 mm.
(Example) Reading: 000003FFH = 1023 (decimal)

= 10.23 mm

* If current positions are read as hexadecimals, negative values

are indicated by 2’s complements.

2.9 (1)

Completed

position
number

(simple

alarm
code)

16 bits

PM 1 ~
PM512

16-bit integer.
When the actuator has moved to the target position and entered
the positioning band, the position number corresponding to the
completed position is output.
“0” is output when no position movement has been performed
yet or while the actuator is moving.
If an alarm occurs (the status signal ALM turns ON), a
corresponding simple alarm code (refer to the operation manual
for the controller) will be output.

2.9 (1)

b15 EMGS

Emergency stop: An emergency stop is actuated when this
signal turns ON.

2.7.7 (2)

b14 PWR

Controller ready: This signal turns ON when the controller
becomes ready.

2.7.7 (1)

b13 ZONE2

Zone 2: This signal turns ON when the current position is inside
the specified zone.

2.7.7 (12)

b12 ZONE1

Zone 1: This signal turns ON when the current position is inside
the specified zone.

2.7.7 (12)

b11 PZONE

Position zone: This signal turns ON when the current position is
inside the specified position zone.

2.7.7 (12)

b10 MODES

Teaching mode signal: This signal is ON while the teaching
mode is selected.

2.7.7 (16)

b9 WEND

Position data read complete: This signal turns ON when reading
is complete.

2.7.7 (17)

b8 RMDS

Operation mode status: This signal is OFF when the current
mode is AUTO, or ON when the current mode is MANU.

2.7.7 (19)

b7
b6

- Not

available.

-

b5 PSFL

Load missed in push motion: This signal turns ON when the
actuator missed the load in push-motion operation.

2.7.7 (23)

b4

SV

Ready: This signal turns ON when the servo turns ON.

2.7.7 (5)

b3

ALM

Alarm: This signal turns ON when an alarm occurs.

2.7.7 (3)

b2 MOVE

Moving signal: This signal remains ON while the actuator is
moving.

2.7.7 (9)

b1 HEND

Home return complete: This signal turns ON when home return
is completed.

2.7.7 (6)

PLC in

put

Status

signal

b0 PEND

Position complete signal: This signal turns ON when positioning
is completed.

2.7.7 (10)