3.10 DeviceNet

Parameters


Parameters relating to DeviceNet are Nos. 84 to 87, 90 and 159.

Category: C: External interface parameter

No. Category Symbol

Name

Factory-set

default

1

~

83

For parameter Nos. 1 to 83, refer to the
operation manual for the controller.

84

C

FMOD

Fieldbus operation mode

0

85

C

NADR

Fieldbus node address

63

86

C

FBRS

Field bus baud rate

0

87 C

NTYP

Network

type

2

90

C

FMIO

Fieldbus I/O format

3

159

C

FBVS

FB half direct mode speed unit

0

z Fieldbus operation mode (No. 84, FMOD)
Specify the operation mode in parameter No. 84 using a value between 0 and 4.

Value set in

parameter No. 84

Mode

Number of

occupied channels

Description

0 (Factory setting) Remote I/O mode 1CH

Operation using PIOs (24-V I/Os) is performed
via DeviceNet.

1

Position/simple
direct mode

4CH

The actuator can be operated by specifying the
target position directly and numerically or
based on a value in the position data table.
Other values required for operation are set in
the position data table.

2

Half direct mode

8CH

The actuator is operated by specifying all data
other than the target position, such as speed,
acceleration/deceleration, push-motion current,
directly and numerically.

3

Full direct mode

16CH

The actuator is operated by directly specifying
all values relating to position control.

4

Remote I/O mode
2

6CH

The functions available in the remote I/O mode
are combined with the current-position read
mode and current-speed read mode.

z Fieldbus node address (No. 85, NADR)
Specify the node address of the remote station in parameter No. 85.

Setting range: 0 to 63

(The factory setting is “63.”)

z Fieldbus baud rate (No. 86, FBRS)
The baud rate is automatically set to the same value as the baud rate set in the master. Accordingly, you need not
set the baud rate.