2. ACON-C/CG,

PCON-C/CG


58

(14) Jog-speed/inch-distance switching (JVEL) [PLC output signal]

This signal is used to switch between the jog speed parameter when jog operation is selected, and the inch
distance parameter when inch operation is selected.

JVEL signal

Jog operation: JISL = OFF

Inch operation: JISL = ON

OFF

Parameter No. 26, “Jog speed”

Parameter No. 26, “Jog speed”
Parameter No. 48, “Inch distance”

ON

Parameter No. 47, “Jog speed 2”

Parameter No. 47, “Jog speed 2”
Parameter No. 49, “Inch distance 2”


(15) Jog/inch switching (JISL) [PLC output signal]

This signal is used to switch between jog operation and inch operation.
JISL = OFF: Jog operation
JISL = ON: Inch operation
If the JISL signal turns ON (inch) while the actuator is moving by jogging, the actuator will decelerate to a stop and
then switch to the inch function.
If the JISL signal turns ON (jog) while the actuator is moving by inching, the actuator will complete the movement
and then switch to the jog function.
The table below summarizes the relationship of the ON/OFF statuses of the JISL signal and
jog-speed/inch-distance switching (JVEL) signal.

Jog operation

Inch operation

JISL OFF

ON

Speed

Parameter No. 26, “Jog speed”

Parameter No. 26, “Jog speed”

Travel

-

Parameter No. 48, “Inch distance”

JVEL=OFF

Acceleration/
deceleration

Rated value (The specific value
varies depending on the actuator.)

Rated value (The specific value
varies depending on the actuator.)

Speed

Parameter No. 47, “Jog speed 2”

Parameter No. 47, “Jog speed 2”

Travel

-

Parameter No. 49, “Inch distance 2”

JVEL=ON

Acceleration/
deceleration

Rated value (The specific value
varies depending on the actuator.)

Rated value (The specific value
varies depending on the actuator.)

Operation

When the JOG+/JOG- signal is ON

Upon detection of the leading (ON)
edge of the JOG+/JOG- signal