3. PCON-CA/CF

A


119

Signal type

Bits

Symbol

Description

Details

b15 EMGS

Emergency stop: An emergency stop is actuated when this
signal turns ON.

3.7.7 (2)

b14 PWR

Controller ready: This signal turns ON when the controller
becomes ready.

3.7.7 (1)

b13 ZONE2

Zone 2: This signal turns ON when the current position is inside
the specified zone.

3.7.7 (12)

b12 ZONE1

Zone 1: This signal turns ON when the current position is inside
the specified zone.

3.7.7 (12)

b11 PZONE

Position zone: This signal turns on when the current position is
inside the position zone.

3.7.7 (12)

b10 LOAD

Load Output Judgment:
“ON” for Reached “OFF” for Not reached
[Refer to the instruction manual for the controller main body for
more information.]

3.7.7 (26)

b9 TRQS

Torque Level:
“ON” for Reached “OFF” for Not Reached
[Refer to the instruction manual for the controller main body for
more information.]

3.7.7 (27)

b8 RMDS

Operation mode status: This signal is OFF when the current
mode is AUTO, or ON when the mode is MANU.

3.7.7 (19)

b7 GHMS

Home return in progress: This signal remains ON while home
return is in progress.

3.7.7 (6)

b6 PUSHS

Push motion in progress: This signal remains ON while
push-motion operation is in progress.

3.7.7 (25)

b5 PSFL

Load missed in push motion: This signal turns ON when the
actuator missed the load in push-motion operation.

3.7.7 (23)

b4

SV

Ready: This signal turns ON when the servo turns ON.

3.7.7 (5)

b3

ALM

Alarm: This signal turns ON when an alarm occurs.

3.7.7 (3)

b2 MOVE

Moving signal: This signal remains ON while the actuator is
moving.

3.7.7 (9)

b1 HEND

Home return complete: This signal turns ON when home return
is completed.

3.7.7 (6)

PLC in

put

Status

signal 2

b0 PEND

Position complete signal: This signal turns ON when positioning
is completed.

3.7.7 (10)