IAI America PCON-CFA User Manual
Page 28
2. ACON-C/CG,
PCON-C/CG
22
(3) I/O signal assignments
The signals assigned to the controller’s I/O ports vary depending on the setting of parameter No. 25.
(For details, refer to the operation manual for the controller.)
Setting of Parameter No. 25
Positioning mode
Teaching mode
256-point mode
0 1 2
Category
Port
No.
Symbol
Signal name
Symbol
Signal name
Symbol
Signal name
0
PC1 PC1 PC1
1
PC2 PC2 PC2
2
PC4 PC4 PC4
3
PC8 PC8 PC8
4
PC16 PC16 PC16
5 PC32
Command position
number
PC32
Command position
number
PC32
6 -
MODE
Teaching mode
command
PC64
7 -
JISL
Jog/inch
switching
PC128
Command position
number
8 -
Not available.
JOG+ +Jog
-
Not
available.
9 BKRL
Forced brake
release
JOG- -Jog BKRL
Forced brake
release
10 RMOD Operation
mode RMOD
Operation mode
RMOD
Operation mode
11
HOME
Home return
HOME
Home return
HOME
Home return
12
*STP Pause *STP Pause *STP Pause
13 CSTR Positioning
start
CSTR/
PWRT
Positioning
start/position-data
read command
CSTR Positioning
start
14
RES Reset RES Reset RES Reset
PLC
output
o
ACON
input
15
SON
Servo ON command
SON
Servo ON command
SON
Servo ON command
0 PM1
PM1
PM1
1 PM2
PM2
PM2
2 PM4
PM4
PM4
3 PM8
PM8
PM8
4
PM16 PM16 PM16
5 PM32
Completed position
number
PM32
Completed position
number
PM32
6 MOVE Moving
signal MOVE
Moving signal
PM64
7 ZONE1
Zone
1
MODES
Teaching mode
signal
PM128
Completed position
number
8 PZONE Position
zone PZONE
Position
zone PZONE Position
zone
9 RMDS
Operation mode
status
RMDS
Operation mode
status
RMDS
Operation mode
status
10 HEND
Home return
complete
HEND
Home return
complete
HEND
Home return
complete
11 PEND
Position complete
signal
PEND/
WEND
Position complete
signal/position-data
read complete
PEND
Position complete
signal
12
SV Ready SV Ready SV Ready
13 *EMGS Emergency
stop *EMGS
Emergency stop
*EMGS
Emergency stop
14
*ALM Alarm *ALM Alarm *ALM Alarm
ACON
output
o
PLC input
15
- Not
available. - Not
available. - Not
available.
The signals indicated by * are ON in a normal state.
The signals denoted by “Not available” are not controlled (their ON/OFF status is indeterminable).
ACON