User adjustable gain references, See chapter, 5b/c in – ALLIED Vision Technologies Pike F-1600 User Manual
Page 377: Table 199, Default gain references of pike models, Table 199: default gain references of pike models, Chapter
Configuration of the camera
PIKE Technical Manual V5.1.2
377
User adjustable gain references
This register gives the user the possibility (via direct access) to modify the gain
references. Modified values are stored automatically without further user
action and are also stored on restart.
To reload default gain references (which are programmed at personalization)
within the camera: set flag m_bDefGainRef=1
In the following table you find the default gain references of all Pike models:
*: Firmware package version 00.03.00.01 or earlier
Offset
Name
Field
Bit
Description
0xF1002000
AFEREFERENCES
Presence_Inq
[0]
Indicates presence of this feature
(read only)
---
[1..4]
Reserved
m_bDefGainRef [5]
Reload default gain references, if
this flag is set.
---
[6..31]
Reserved
0xF1002004
GAINREFERENCE
m_GainRef
[0..31]
Gain reference (0..511)
Table 198: Advanced register: User adjustable gain references
Pike model
Default gain reference (decimal)
Default gain reference (hex)
Pike F-032B/C
200
C8h
Pike F-100B/C
210
D2h
Pike F-145B/C (15fps)
30 (15*)
1Eh (0Fh*)
Pike F-145B/C (30fps)
85 (15*)
55h (0Fh*)
Pike F-210B/C
215
D7h
Pike F-421B/C
200
C8h
Pike F-505B/C
205 (130*)
CDh (82h*)
Pike F-1100B/C
228
E4h
Pike F-1600B/C
193
C1h
Table 199: Default gain references of Pike models