Table 157: time base id – ALLIED Vision Technologies Pike F-1600 User Manual
Page 335

Configuration of the camera
PIKE Technical Manual V5.1.2
335
The ExpOffset field specifies the camera specific exposure time offset in micro-
seconds (μs). This time (which should be equivalent to
on page 215) has to be added to the exposure time
(set by any shutter register) to compute the real exposure time.
The ExpOffset field might be zero for some cameras: this has to be assumed as
an unknown exposure time offset (according to former software versions).
Note
Time base can only be changed when the camera is in idle state
and becomes active only after setting the shutter value.
ID
Time base in μs
0
1
1
2
2
5
3
10
4
20
Default value
5
50
6
100
7
200
8
500
9
1000
Table 157: Time base ID
Note
The ABSOLUTE VALUE CSR register, introduced in IIDC V1.3, is
not implemented.