Secure image signature (SIS)

Secure image signature (SIS) is the synonym for data, which is inserted into an
image to improve or check image integrity.

All Pike models can insert

Time stamp (1394 bus cycle time at the beginning of integration)

Frame counter (frames read out of the sensor)

Trigger counter (external trigger seen only)

Various camera settings

into a selectable line position within the image. Frame counter and trigger
counter
are available as advanced registers to be read out directly.

Advanced register: SIS

The SIS feature is controlled by the following advanced feature register:

Enabling this feature, SIS data will be inserted into any captured image. The
size of SIS data depends on the selected SIS format.

The LineNo

field indicates at which line the SIS data will be inserted.

Enter a

positive value from 0..HeightOfImage to specify a position relative to the
top of the image. LinePos=0 specifies the very first image line.

negative value from -1..-HeightOfImage to specify a position relative to
the bottom of the image. LinePos=-1 specifies the very last image line.

Note

This register is different to the Marlin time stamp (600) regis-
ter!

Register

Name

Field

Bit

Description

0xF1000630 SIS

Presence_Inq

[0]

Indicates presence of this feature
(read only)

---

[1..5]

Reserved

ON_OFF

[6]

SIS mode on/off

---

[7..15]

Reserved

LineNo

[16..31] SIS data position inside an image

0xF1000634

UserValue

[0..31]

User provided value for sequence
mode to be placed into the SIS area
of an image

Table 184: Advanced register: secure image signature (SIS)

This manual is related to the following products: