PWM: Examples in practice
In this chapter we give you two examples, how to write values in the PWM regis-
ters. All values have to be written in microseconds (μs) in the PWM registers,
therefore remember always the factor 10
-6
s.
Example 1:
Set PWM with 1kHz at 30% pulse width.
Example 2:
Set PWM with 250 Hz at 12% pulse width.
Formula 2: PWM example 1
Formula 3: PWM example 2
RegPeriod
1
frequency
6
–
10 s
--------------------------------------
1
1kHz
6
–
10 s
---------------------------
1000
=
=
=
RegPulseWidth
RegPeriod
30%
1000
30%
300
=
=
=
RegPeriod
1
frequency
6
–
10 s
--------------------------------------
1
250Hz
6
–
10 s
------------------------------
4000
=
=
=
RegPulseWidth
RegPeriod
12%
4000
12%
480
=
=
=