beautypg.com

Auto shutter control, Table 166, Advanced register: auto shutter control – ALLIED Vision Technologies Pike F-1600 User Manual

Page 347: Table 166: advanced register: auto shutter con, Trol

background image

Configuration of the camera

PIKE Technical Manual V5.1.2

347

Auto shutter control

The table below illustrates the advanced register for auto shutter control. The
purpose of this register is to limit the range within which auto shutter operates.

When both auto shutter and auto gain are enabled, priority is given to increas-
ing shutter when brightness decreases. This is done to achieve the best image
quality with lowest noise.

For increasing brightness, priority is given to lowering gain first for the same
purpose.

MinValue and MaxValue limits the range the auto shutter feature is allowed to
use for the regulation process. Both values are initialized with the minimum
and maximum value defined in the standard SHUTTER_INQ register (multiplied
by the current active timebase).

If you change the MinValue and/or MaxValue and the new range exceeds the
range defined by the SHUTTER_INQ register, the standard SHUTTER register will
not show correct shutter values. In this case you should read the
EXTENDED_SHUTTER register for the current active shutter time.

Changing the auto shutter range might not affect the regulation, if the regula-
tion is in a stable condition and no other condition affecting the image bright-
ness is changed.

Register

Name

Field

Bit

Description

0xF1000360 AUTOSHUTTER_CTRL

Presence_Inq

[0]

Indicates presence of this
feature (read only)

---

[1..31]

Reserved

0xF1000364 AUTOSHUTTER_LO

---

[0..5]

Reserved

MinValue

[6..31]

Minimum auto shutter value

lowest possible value: 10 μs

0xF1000368 AUTOSHUTTER_HI

---

[0..5]

Reserved

MaxValue

[6..31]

Maximum auto shutter value

Table 166: Advanced register: Auto shutter control

Note

Values can only be changed within the limits of shutter
CSR.

Changes in auto exposure register only have an effect
when auto shutter is enabled.

Auto exposure limits are: 50..205 (SmartViewCtrl1
tab
: Target grey level)

This manual is related to the following products: