Advanced register: frame counter – ALLIED Vision Technologies Pike F-1600 User Manual
Page 366
Configuration of the camera
PIKE Technical Manual V5.1.2
366
Advanced register: frame counter
The frame counter feature is controlled by the following advanced feature reg-
ister:
Having this feature enabled, the current frame counter value (images read out
of the sensor, equivalent to # FrameValid) will be inserted as a 32-bit integer
value into any captured image.
Setting the Reset flag to 1 resets the frame counter to 0: the Reset flag is self-
cleared.
Additionally there is a register for direct read out of the frame counter value.
Note
Different to Marlin SIS:
Register 610 is only to be used to reset the frame counter.
Register
Name
Field
Bit
Description
0xF1000610 FRMCNT_STAMP
Presence_Inq
[0]
Indicates presence of this feature
(read only)
Reset
[1]
Reset frame counter
---
[2..31]
Reserved
0xF1000614 FRMCNT
[0..31]
Frame counter
Table 187: Advanced register: Frame counter
Note
The 4 bytes of the frame counter value will be inserted as the
5th to 8th byte of a line.