Advanced register: frame counter

The frame counter feature is controlled by the following advanced feature reg-
ister:

Having this feature enabled, the current frame counter value (images read out
of the sensor, equivalent to # FrameValid) will be inserted as a 32-bit integer
value into any captured image.

Setting the Reset flag to 1 resets the frame counter to 0: the Reset flag is self-
cleared.

Additionally there is a register for direct read out of the frame counter value.

Note

Different to Marlin SIS:

Register 610 is only to be used to reset the frame counter.

Register

Name

Field

Bit

Description

0xF1000610 FRMCNT_STAMP

Presence_Inq

[0]

Indicates presence of this feature
(read only)

Reset

[1]

Reset frame counter

---

[2..31]

Reserved

0xF1000614 FRMCNT

[0..31]

Frame counter

Table 187: Advanced register: Frame counter

Note

The 4 bytes of the frame counter value will be inserted as the
5th to 8th byte of a line.