Description of the data path

PIKE Technical Manual V5.1.2

202

To configure this feature in access control register (CSR):

Offset

Name

Field

Bit

Description

000h

SERIAL_MODE_REG

Baud_Rate

[0..7]

Baud rate setting

WR: Set baud rate

RD: Read baud rate

0: 300 bps

1: 600 bps

2: 1200 bps

3: 2400 bps

4: 4800 bps

5: 9600 bps

6: 19200 bps

7: 38400 bps

8: 57600 bps

9: 115200 bps

10: 230400 bps

Other values reserved

Char_Length

[8..15]

Character length setting

WR: Set data length (7 or 8 bit)

RD: Get data length

7: 7 bits

8: 8 bits

Other values reserved

Parity

[16..17] Parity setting

WR: Set parity

RD: Get parity setting

0: None

1: Odd

2: Even

Stop_Bit

[18..19] Stop bits

WR: Set stop bit

RD: Get stop bit setting

0: 1

1: 1.5

2: 2

---

[20..23] Reserved

Buffer_Size_Inq [24..31] Buffer Size (RD only)

This field indicates the maximum size of
receive/transmit data buffer.

If this value=1, Buffer_Status_Control
and SIO_Data_Register Char 1-3 should
be ignored.

Table 64: Serial input/output control and status register (SIO CSR)