Description of the data path

PIKE Technical Manual V5.1.2

136

Channel balance

All KODAK PIKE sensors and the SONY sensor (of Pike F-505) are read out via two
channels: the first channel for the left half of the image and the second channel
for the right half of the image (divided by a central vertical line).

All KODAK equipped cameras come with a sensor-specific pre-adjusted channel
balance.

However in some cases it may be advantageous to carry out a fine adjustment
with the so-called channel balance.

To carry out a gain adjustment in an advanced register: see

Table 172:

Advanced register: Channel balance

on page 352.

To carry out a dual-tap offset adjustment in an advanced register: see

Table

173: Advanced register: Dual-tap offset adjustment

on page 352

Channel adjustment with SmartView (

1.5)

Prerequisites:

Test sheet with continuous b/w gradient

PIKE camera with defocused lens

PIKE color cameras set to RAW8 or RAW16 (debayering: none)

In case of using AOI, be aware that the middle vertical line (+/- 20 pixel)
is part of the AOI.

To carry out an adjustment in SmartView, perform the following steps:

1.

In SmartView click ExtrasAdjust channels... or use Alt+Ctrl+A.

Note

PIKE F-1100 and PIKE F-1600 can also be used in single-tap
readout mode, to prevent channel balance related problems.

See

Sensor digitization taps (Pike F-1100/1600 only)

on page

360ff.

Note

Automatic adjustment of gain (and offset) is implemented in
SmartView and is not available on register basis.