beautypg.com

Auto gain control, Er: see, Table – ALLIED Vision Technologies Pike F-1600 User Manual

Page 348: Advanced register: auto gain control, Table 167: advanced register: auto gain control

background image

Configuration of the camera

PIKE Technical Manual V5.1.2

348

If both auto gain and auto shutter are enabled and if the shutter is at its upper
boundary and gain regulation is in progress, increasing the upper auto shutter
boundary has no effect on auto gain/shutter regulation as long as auto gain
regulation is active.

Auto gain control

The table below illustrates the advanced register for auto gain control.

MinValue and MaxValue limits the range the auto gain feature is allowed to use
for the regulation process. Both values are initialized with the minimum and
maximum value defined in the standard GAIN_INQ register.

Changing the auto gain range might not affect the regulation, if the regulation
is in a stable condition and no other condition affecting the image brightness is
changed.

If both auto gain and auto shutter are enabled and if the gain is at its lower
boundary and shutter regulation is in progress, decreasing the lower auto gain
boundary has no effect on auto gain/shutter regulation as long as auto shutter
regulation is active.

Both values can only be changed within the range defined by the standard
GAIN_INQ register.

Note

As with the Extended Shutter the value of MinValue and
MaxValue must not be set to a lower value than the minimum
shutter time.

Register

Name

Field

Bit

Description

0xF1000370 AUTOGAIN_CTRL

Presence_Inq

[0]

Indicates presence of this
feature (read only)

---

[1..3]

Reserved

MaxValue

[4..15]

Maximum auto gain value

---

[16..19]

Reserved

MinValue

[20..31]

Minimum auto gain value

Table 167: Advanced register: Auto gain control