beautypg.com

Debounce time, Chapter, See chapter – ALLIED Vision Technologies Pike F-1600 User Manual

Page 214

background image

Controlling image capture

PIKE Technical Manual V5.1.2

214

Debounce time

This register controls the debounce feature of the cameras input pins. The
debounce time can be set for each available input separately.

Increment is 500 ns

Debounce time is set in Time x 500 ns

Minimum debounce time is 1.5 μs 3 x 500 ns

Maximum debounce time is ~16 ms (2

15

-1) x 500 ns

Note

The pulse width (total time of high and low pulses) must be
greater than the debounce time.

Offset

Name

Field

Bit

Description

0xF1000840

IO_INP_DEBOUNCE_1

Presence_Inq

[0]

Indicates presence of this feature
(read only)

---

[2..7]

Reserved

Time

[8..31]

Debounce time in steps of 500 ns
(24 bit) see examples above

0xF1000844

MinValue

[0..31]

Minimum debounce time

0xF1000848

MaxValue

[0..31]

Maximum debounce time

0xF100084C

---

[0..31]

Reserved

0xF1000850

IO_INP_DEBOUNCE_2

same as IO_INP_DEBOUNCE_1

0xF1000860

IO_INP_DEBOUNCE_3

same as IO_INP_DEBOUNCE_1

0xF1000870

IO_INP_DEBOUNCE_4

same as IO_INP_DEBOUNCE_1

0xF1000880

Reserved

0xF1000890

Reserved

0xF10008A0

Reserved

0xF10008B0

Reserved

Table 71: Advanced register: Debounce time for input ports

Note

The camera corrects invalid values automatically.

This feature is not stored in the user settings.