beautypg.com

Changing the parameters within a sequence – ALLIED Vision Technologies Pike F-1600 User Manual

Page 232

background image

Controlling image capture

PIKE Technical Manual V5.1.2

232

Changing the parameters within a sequence

To change the parameter set for one image, it is not necessary to modify the
settings for the entire sequence. The image can simply be selected via the
ImageNo field and it is then possible to change the corresponding IIDC V1.31
registers.

Points to pay attention to when changing the
parameters

Note

If the ApplyParameters flag is used when setting the
parameters, all not-configured values are set to default
values. As changing a sequence normally affects only the
value of a specific register, and all other registers should
not be changed, the ApplyParameters flag may not be
used here.

The values stored for individual images can no longer be
read.

If the camera is switched into sequence mode, the
changes to the IIDC V1.31 registers for the image speci-
fied in ImageNo take immediate effect.

Sequence mode requires firmware 3.x and special care if
changing image size and frame rate related parameters.
This is because these changes not only affect settings in
the camera but also require corresponding settings in the
receiving software in the PC (e.g. FirePackage).

Caution

Incorrect handling may lead to image corruption or loss of
subsequent images
.

Please ask for detailed support when you want to use this
feature.