Page 435: T: timer setting, Operand specifications, Cx-programmer settings
2-399
2 Instructions
CP1E CPU Unit Instructions Reference Manual(W483)
Oth
er
I
n
stru
ctio
ns
2
WDT
WDT
Applicable Program Areas
Operands
T: Timer setting
Specifies the watchdog timer setting between 0000 and 0064 hexadecimal or between &0000 and
&0100 decimal.
Operand Specifications
Flags
Related PLC Setup Settings
CX-Programmer settings
Instruction
Mnemonic
Variations
Function
code
Function
EXTEND MAXIMUM
CYCLE TIME
WDT
@WDT
094
Extends the maximum cycle time, but only for the cycle
in which the instruction is executed. WDT(094) can be
used to prevent errors for long cycle times when a
longer cycle time is temporarily required for special
processing.
Symbol
WDT
Area
Step program areas
Subroutines
Interrupt tasks
Usage
OK
OK
OK
Operand
Description
Data type
Size
T
Timer setting
Constants only
1
Area
Word addresses
Indirect DM addresses
Constants
CF
Pulse bits
TR bits
CIO
WR
HR
AR
T
C
DM
@DM
*DM
T
---
---
---
---
---
---
---
---
---
OK
---
---
---
Operand
Description
Data type
Error Flag
P_ER
• ON if the watchdog timer setting exceeds 1 second.
• OFF in all other cases.
T: Timer setting
WDT(094)
T