Applicable program areas operands, Flags, 2 instructions – Omron SYSMAC CP CP1E-N@@D@-@ User Manual
Page 410: C: control word operand specifications
2 Instructions
2-374
CP1E CPU Unit Instructions Reference Manual(W483)
RXD
Applicable Program Areas
Operands
C: Control Word
Operand Specifications
Flags
Instruction
Mnemonic
Variations
Function
code
Function
RECEIVE
RXD
@RXD
235
Reads the specified number of bytes of data from
the CPU Unit’s built-in RS-232C port or the Serial
Option Board port.
Symbol
RXD
Area
Step program areas
Subroutines
Interrupt tasks
Usage
OK
OK
OK
Operand
Description
Data type
Size
D
First destination word
UINT
Variable
C
Control word
UINT
1
N
Number of bytes to store 0000 to 0100 hex (0 to 256 decimal)
UINT
1
Area
Word addresses
Indirect DM addresses
Constants
CF
Pulse bits
TR bits
CIO
WR
HR
AR
T
C
DM
@DM
*DM
D
OK
OK
OK
OK
OK
OK
OK
OK
OK
---
---
---
---
C, N
OK
Name
Label
Operation
Error Flag
P_ER
• ON if no-protocol mode is not set in the PLC Setup.
• ON if the value of C is not within range.
• ON if the value for N is not between 0000 and 0100 hex.
• OFF in all other cases.
RXD(235)
D
C
N
D: First destination word
C: Control word
N: Number of bytes to store
0000 to 0100 hex (0 to 256 decimal)
C
8
12
3
4
15
0
7
11
Byte order
0 Hex: Most significant byte to least significant byte
1 Hex: Lest significant byte to most significant byte
CS and DR signal monitoring
0: No CS and DR signal monitoring
1: CS signal monitoring
2: DR signal monitoring
3: CS and DR signal monitoring.
Always 0
Serial port specifier
1: CPU Unit’s RS-232C port
2: Serial Option Board port