Applicable Program Areas
Operands
P: Port Specifier
F: Frequency
F specifies the frequency of the PWM output between 2.0 and 6,553.5 Hz (0.1 Hz units, 0014 to FFFF
hex), or between 2 and 32,000 Hz (2 Hz units, 0002 to 7D00 hex).
D: Duty Factor
• 0.0% to 100.0% (0.1% units, 0000 to 03E8 hex)
D specifies the duty factor of the PWM output, i.e., the percentage of time that the output is ON.
Instruction
Mnemonic
Variations
Function
code
Function
PULSE WITH VARIABLE
DUTY FACTOR
PWM
@PWM
891
PWM(891) is used to output pulses with the speci-
fied duty factor from the specified port.
Symbol
PWM
Area
Step program areas
Subroutines
Interrupt tasks
Usage
OK
OK
OK
Operand
Description
Data type
Size
P
Port specifier
---
1
F
Frequency
---
1
D
Duty factor
---
1
P
Port
1000 hex
PWM output 0 (duty factor: in increments of 1%, frequency 0.1 Hz)
1100 hex
PWM output 0 (duty factor: in increments of 1%, frequency 1 Hz)
P: Port specifier
F: Frequency
D: Duty factor
PWM
P
F
D