beautypg.com

Cnt/cntx, Applicable program areas operands, Flags – Omron SYSMAC CP CP1E-N@@D@-@ User Manual

Page 116: 2 instructions, N: counter number, S: set value, Operand specifications

background image

2 Instructions

2-80

CP1E CPU Unit Instructions Reference Manual(W483)

CNT/CNTX

Applicable Program Areas

Operands

N: Counter Number

The counter number must be between 0000 and 0255 (decimal).

S: Set Value

CNT (BCD): #0000 to #9999
CNTX (Binary): &0 to &65535 (decimal) or #0000 to #FFFF (hex)

Operand Specifications

Flags

Instruction

Mnemonic

Variations

Function

code

Function

COUNTER

CNT/CNTX

---

546

CNT/CNTX(546) operates a decrementing
counter.

Symbol

CNT

CNTX

BCD

Binary

Area

Step program areas

Subroutines

Interrupt tasks

Usage

OK

OK

OK

Operand

Description

Data type

Size

CNT

CNTX

N

Counter Number

COUNTER

COUNTER

1

S

Set Value

WORD

UINT

1

Area

Word addresses

Indirect DM addresses

Constants

CF

Pulse bits

TR bits

CIO

WR

HR

AR

T

C

DM

@DM

*DM

N

---

---

---

---

---

OK

---

---

---

---

---

---

---

S

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

Name

Label

Operation

Error Flag

P_ER

ON if in BCD mode and S does not contain BCD data.

OFF in all other cases.

CNT

N

S

Count input

Reset input

N: Counter number

S: Set value

CNTX(546)

N

S

Count input

Reset input

N: Counter number

S: Set value