Puls, Applicable program areas operands, 2 instructions – Omron SYSMAC CP CP1E-N@@D@-@ User Manual

Page 359: Operand specifications

background image

2-323

2 Instructions

CP1E CPU Unit Instructions Reference Manual(W483)

High-speed

Counter/Pulse

Ou

tp
ut I

n

stru

ctio

ns

2

PULS

PULS

Applicable Program Areas

Operands

P: Port specifier

T: Pulse type

N and N+1: Number of pulses

The actual number of movement pulses that will be output are as follows:

For relative pulse output, the number of movement pulses = the set number of pulses.
For absolute pulse output, the number of movement pulses = the set number of pulses - the PV.

Operand Specifications

Instruction

Mnemonic

Variations

Function

code

Function

SET PULSES

PULS

@PULS

886

PULS(886) is used to set the pulse output amount (number of out-
put pulses).

Symbol

PULS

Area

Step program areas

Subroutines

Interrupt tasks

Usage

OK

OK

OK

Operand

Description

Data type

Size

P

Port specifier

---

1

T

Pulse type

---

1

N

Number of pulses

DINT

2

P

Port

0000 hex

Pulse output 0

0001 hex

Pulse output 1

T

Pulse type

0000 hex

Relative

0001 hex

Absolute

Area

Word addresses

Indirect DM addresses

Constants

CF

Pulse bits

TR bits

CIO

WR

HR

AR

T

C

DM

@DM

*DM

P, T

---

---

---

---

---

---

---

---

---

OK

---

---

---

N

OK

OK

OK

OK

OK

OK

OK

OK

OK

N: Number of pulses

PULS(886)

P

T

N

P: Port specifier

T: Pulse type

N

N+1

0

15

Lower word with number of pulses

Upper word with number of pulses