Date, Applicable program areas operands, Flags – Omron SYSMAC CP CP1E-N@@D@-@ User Manual
Page 421: 2 instructions, S through s+3: new clock setting, Operand specifications
2-385
2 Instructions
CP1E CPU Unit Instructions Reference Manual(W483)
Clo
c
k
I
n
stru
ctio
ns
2
D
A
TE
DATE
Applicable Program Areas
Operands
S through S+3: New Clock Setting
Note S through S+3 must be in the same data area.
Operand Specifications
Flags
Instruction
Mnemonic
Variations
Function
code
Function
CLOCK ADJUSTMENT
DATE
@DATE
735
Changes the internal clock setting to the setting in
the specified source words.
Symbol
DATE
Area
Step program areas
Subroutines
Interrupt tasks
Usage
OK
OK
OK
Operand
Description
Data type
Size
S
First source word
LWORD
4
Area
Word addresses
Indirect DM addresses
Constants
CF
Pulse bits
TR bits
CIO
WR
HR
AR
T
C
DM
@DM
*DM
S
OK
OK
OK
OK
OK
OK
OK
OK
OK
---
---
---
---
Name
Label
Operation
Error Flag
P_ER
• ON if the new clock setting in S through S+3 is not within the specified range.
• OFF in all other cases.
• ON when DATE instruction is executed for CP1E-E
- .
S: First source word
DATE(735)
S
15
8
0
7
S
15
8
0
7
S+1
15
8
0
7
S+2
15
8
0
7
S+3
Seconds:
00 to 59 (BCD)
Minutes: 00 to 59 (BCD)
Hour:
00 to 23 (BCD)
Day: 01 to 31 (BCD)
Month:
01 to 12 (BCD)
Year: 00 to 99 (BCD)
Always set to 00.
Day of
the week: 00 = Sunday
01 = Monday
02 = Tuesday
03 = Wednesday
04 = Thursday
05 = Friday
06 = Saturday