2 instructions – Omron SYSMAC CP CP1E-N@@D@-@ User Manual
Page 185
2-149
2 Instructions
CP1E CPU Unit Instructions Reference Manual(W483)
Increm
ent/D
ecrement
In
stru
ctio
ns
2
+
+
/+
+L
Operation of @++(590)/@++L(591)
The up-differentiated variation is used in the following example, so the content of D100 will be incre-
mented by 1 only when CIO 0.00 has gone from OFF to ON.
The up-differentiated variation is used in the following example, so the content of D101 and D100 will be
incremented by 1 only when CIO 0.00 has gone from OFF to ON.
0 0 1 9
Wd: D100
0 0 1 A
Incremented every cycle
while CIO 0.00 is ON.
Wd: D100
@++
D100
+1
0.00
0.00
Wd+1: D101
Wd: D100
Wd+1: D101
Wd: D100
Increment
Increment
: Execution of @++(590) or @++L(591)
Incremented only for
up-differentiation.
+1
@++L
D100
0.00
0 0 0 0
F F F F
0 0 0 1
0 0 0 0
This manual is related to the following products: