beautypg.com

Bcmp, Applicable program areas operands, Flags – Omron SYSMAC CP CP1E-N@@D@-@ User Manual

Page 139: B: first word of block r: result word, 2 instructions, Operand specifications

background image

2-103

2 Instructions

CP1E CPU Unit Instructions Reference Manual(W483)

Co

mp

ari
s

on I

n

stru

ctio

ns

2

BCMP

BCMP

Applicable Program Areas

Operands

Operand Specifications

Flags

Instruction

Mnemonic

Variations

Function

code

Function

BLOCK COMPARE

BCMP

@BCMP

068

Compares the source data to 16 ranges (defined
by 16 lower limits and 16 upper limits) and turns
ON the corresponding bit in the result word when
the source data is within a range.

Symbol

BCMP

Area

Step program areas

Subroutines

Interrupt tasks

Usage

OK

OK

OK

Operand

Description

Data type

Size

S

Source data

WORD

1

B

First word of block

WORD

32

R

Result word

UINT

1

B: First word of block

R: Result word

Area

Word addresses

Indirect DM addresses

Constants

CF

Pulse bits

TR bits

CIO

WR

HR

AR

T

C

DM

@DM

*DM

S

OK

OK

OK

OK

OK

OK

OK

OK

OK

OK

---

---

---

B

---

D

Name

Label

Operation

Error Flag

P_ER

OFF

Equals Flag

P_EQ

ON if the result word is 0000.

(S is not within any of the 16 ranges.)

OFF in all other cases.

BCMP(068)

S

B

R

S: Source data

B: First word of block

R: Result word

B

B+1

B+2

B+3

B+30

B+31

Lower limit value 0

Upper limit value 0

Lower limit value 1

Upper limit value 1

Lower limit value 15

Upper limit value 15

15

0

14

R

1

Comparison result for S and
range B

↔ B+1

Comparison result for S and
range B+2

↔ B+3

Comparison result for S and
range B+28

↔ B+29

Comparison result for S and
range B+30

↔ B+31