High-speed counter/pulse output instructions, Applicable program areas operands, 2 instructions – Omron SYSMAC CP CP1E-N@@D@-@ User Manual
Page 344: P: port specifier

2 Instructions
2-308
CP1E CPU Unit Instructions Reference Manual(W483)
High-speed Counter/Pulse Output
Instructions
INI
Applicable Program Areas
Operands
P: Port Specifier
Instruction
Mne-
monic
Varia-
tions
Function
code
Function
MODE CONTROL
INI
@INI
880
INI(880) can be used to execute the following operations
• To start comparison with the high-speed counter comparison table
• To stop comparison with the high-speed counter comparison table
• To change the PV of the high-speed counter.
• To change the PV of interrupt inputs in counter mode.
• To change the PV of the pulse output (origin fixed at 0).
• To stop pulse output.
Symbol
INI
Area
Step program areas
Subroutines
Interrupt tasks
Usage
OK
OK
OK
Operand
Description
Data type
Size
P
Port specifier
WORD
1
C
Control data
UINT
1
NV
First word with new PV
DWORD
2
P
Port
0000 hex
Pulse output 0
0001 hex
Pulse output 1
0010 hex
High-speed counter 0
0011 hex
High-speed counter 1
0012 hex
High-speed counter 2
0013 hex
High-speed counter 3
0014 hex
High-speed counter 4
0015 hex
High-speed counter 5 (Cannot be used in CP1E-E10D - )
1000 hex
PWM(891) output 0
NV: First word with new PV
INI(880)
P
C
NV
P: Port specifier
C: Control data