Multi-function outputs: h2 – Yaskawa G5HHP Drive User Manual
Page 294

User Constants
8.2.6 Terminal Constants: H
8 - 28
Setting
value
Page
Control Methods
Function
Setting
value
Page
Flux
vector
Open
loop
Vector
V/f
w/
PG
V/f
Function
64
External speed search command 3
f
f
f
f
--
65
KEB (deceleration at momentary power loss) command (NO contact)
f
f
f
f
--
66
KEB (deceleration at momentary power loss) command (NO contact)
f
f
f
f
--
71
Speed/torque control change (ON: Torque control)
x
x
x
f
7 - 74
72
Zero-servo command (ON: Zero-servo)
x
x
x
f
7 - 75
77
Speed control (ASR) proportional gain switch (ON: C5-03)
x
x
x
f
7 - 75
J
Multi-function Outputs: H2
C
t t
S tti
F t
Change
Control Methods
Constant
Number
Name
Display
Setting
Range
Factory
Setting
Change
during
Opera-
tion
V/f
V/f
with
PG
Open
Loop
Vector
Flux
Vector
Page
H2-01
Multi-function input
(terminal 53-57)
Terminal 53 Sel
0 to 37
0
x
B
B
B
B
7 - 77
H2-02
Multi-function input
(terminal 19)
Terminal 19 Sel
0 to 37
1
x
B
B
B
B
7 - 77
H2-03
Multi-function input
(terminal 20)
Terminal 20 Sel
0 to 37
2
x
B
B
B
B
7 - 77
Multi-function Output Functions
Control Methods
Setting
value
Function
V/f
V/f
w/
PG
Open
loop
Vec-
tor
Flux
vec-
tor
Page
0
During run ON: run command is ON or voltage is being output)
f
f
f
f
7 - 78
1
Zero-speed
f
f
f
f
7 - 78
2
Frequency agree 1: (Detection width L4-02)
f
f
f
f
7 - 92
3
Desired frequency agree 1 (ON: Output frequency = ±L4-01, detection width in L4-02)
f
f
f
f
7 - 92
4
Frequency (Four) detection 1 (ON: +L4-01≧output frequency≧--L4-01, detection width in L4-02)
f
f
f
f
7 - 92
5
Frequency (Four) detection 2
(ON: Output frequency≧+L4-01 or output frequency≦--L4-01, detection width in L4-02)
f
f
f
f
7 - 92
6
Inverter operation ready
READY: After initialization, no faults
f
f
f
f
--
7
During DC bus undervoltage (UV) detection
f
f
f
f
--
8
During baseblock (ON: during baseblock)
f
f
f
f
--
9
Frequency reference selection (ON: Frequency reference from Operator)
f
f
f
f
--
A
Run command selection (ON: Run command from Operator)
f
f
f
f
--
B
Overtorque detection 1 NO (NO contact: Overtorque detection at ON)
f
f
f
f
7 - 95
C
Loss of frequency reference (Effective when operation selection is “1” for L4-05 frequency reference
missing)
f
f
f
f
7 - 92
D
Braking resistor fault (ON: Resistor overheat or braking transistor fault)
f
f
f
f
--
E
Fault (ON: Faults other than CPF00, CPF01 have occurred.)
f
f
f
f
9 - 2
F
Not used. (Do not set.)
--
--
--
--
--
10
Minor fault (ON: Alarm displayed)
f
f
f
f
9 - 6
11
Fault reset command active
f
f
f
f
--
12
Timer function output
f
f
f
f
7 - 43
13
Frequency agree 2 (Detection width: L4-04)
f
f
f
f
7 - 92
14
Desired frequency agree 2 (ON: Output frequency = L4-03, detection width in L4-04)
f
f
f
f
7 - 92
15
Frequency detection 3 (ON: Output frequency ≦--L4-03, detection width in L4-04)
f
f
f
f
7 - 92
16
Frequency detection 4 (ON: Output frequency ≧--L4-03, detection width in L4-04)
f
f
f
f
7 - 92
8