beautypg.com

Yaskawa G5HHP Drive User Manual

Page 141

background image

6.3 V/f Control

6 - 23

V/f Patterns: 200 to 1200 kW

D

Fixed Torque Characteristics (Settings 0 to 3)

Setting 0

50 Hz

Setting 1

60 Hz

Setting 2

60 Hz

Setting 3

72 Hz

(V)

400

24

12

0 1.3 2.5

50 (Hz)

(V)

400

24

0 1.5 3

60 (Hz)

12

(V)

400

24

0 1.5 3

60 (Hz)

50

12

(V)

400

24

0 1.5 3

60

(Hz)

72

12

D

Variable Torque Characteristics (Settings 4 to 7)

Setting 4

50 Hz

Setting 5

50 Hz

Setting 6

60 Hz

Setting 7

60 Hz

(V)

400

70

0 1.3

25

50 (Hz)

10

(V)

400

100

0 1.3

25

50 (Hz)

12

(V)

400

70

10

0 1.5

30

60 (Hz)

(V)

400

100

0 1.5

30

60 (Hz)

12

D

High Starting Torque Characteristics (Settings 8 to b)

Setting 8

50 Hz

Setting 9

50 Hz

Setting A

60 Hz

Setting B

60 Hz

(V)

400

30

14

0 1.3 2.5

50 (Hz)

(V)

400

40

18

0 1.3 2.5

50 (Hz)

(V)

400

30

14

0 1.5 3

60 (Hz)

(V)

400

40

22

0 1.5 3

60 (Hz)

D

High-speed Operation (Settings C to E)

Setting C

90 Hz

Setting D

120 Hz

Setting E

150 Hz

(V)

400

24

12

0 1.5 3

60

(Hz)

90

(V)

400

24
12

0 1.5 3

60

(Hz)

120

(V)

400

24

12

0 1.5 3

60

(Hz)

150

The voltages above are for 400-V Class Inverters. Multiply the voltages by approx. 1.5 for 575-V Class Inverters.