6 protective functions: l – Yaskawa G5HHP Drive User Manual
Page 248

Advanced Operation
7.5.6 Protective Functions: L
7 - 84
Communication Parity: H5-03
D
Set the parity for MEMOBUS communications.
User
Change
during
Setting
Factory
Valid Access Levels
User
Constant
Number
Name
g
during
Opera-
tion
Setting
Range
Unit Factory
Setting
V/f
Control
V/f with
PG
Open
Loop
Vector
Flux
Vector
H5-03
Communication parity
selection
x
0 to 2
--
0
A
A
A
A
D
Settings
Setting
Function
0
No parity
1
Even parity
2
Odd parity
Stopping Method after Communications Error: H5-04
D
Set the stopping method to used after a communications error is detected.
User
Change
during
Setting
Factory
Valid Access Levels
User
Constant
Number
Name
g
during
Opera-
tion
Setting
Range
Unit Factory
Setting
V/f
Control
V/f with
PG
Open
Loop
Vector
Flux
Vector
H5-04
Stopping method after
communication error
x
0 to 3
--
3
A
A
A
A
D
Settings
Setting
Function
0
Deceleration to stop (deceleration time:C1-02)
1
Coast to stop
2
Emergency stop (deceleration time:C1-09)
3
Continue operation (display only)
Communications Error Detection: H5-05
D
Set whether or not to detect a communications timeout as a communications error.
User
Change
during
Setting
Factory
Valid Access Levels
User
Constant
Number
Name
g
during
Opera-
tion
Setting
Range
Unit Factory
Setting
V/f
Control
V/f with
PG
Open
Loop
Vector
Flux
Vector
H5-05
Communication error
detection selection
x
0, 1
--
1
A
A
A
A
D
Settings
Setting
Function
0
Do not detect as communications error.
1
Detect as communications error.
7.5.6 Protective Functions: L
J
Motor Protection Settings: L1-01, L1-02
Motor Protection Selection: L1-01
User
Change
during
Setting
Factory
Valid Access Levels
User
Constant
Number
Name
g
during
Opera-
tion
Setting
Range
Unit Factory
Setting
V/f
Control
V/f with
PG
Open
Loop
Vector
Flux
Vector
L1-01
Motor protection
selection
x
0, 1
--
1
B
B
B
B
D
Settings
7