7.5 Common Functions
7 - 63
Setting
value
Control Method
Function
Setting
value
Flux
vector
Open
loop
Vector
V/f
w/
PG
V/f
Function
30
PID control integral reset (ON: Reset)
f
f
f
f
60
DC injection braking command (ON: Performs DC injection braking)
f
f
f
f
61
External speed search command 1: Maximum output frequency (ON: speed search)
f
x
f
x
62
External speed search command 2: Set frequency (ON: speed search)
f
x
x
x
63
Energy-saving command (ON: Energy-saving control set for b8-01, b8-02)
f
f
x
x
64
External speed search command 3
f
f
f
f
65
KEB (deceleration at momentary power loss) command (NO contact)
f
f
f
f
66
KEB (deceleration at momentary power loss) command (NO contact)
f
f
f
f
71
Speed/torque control change (ON: Torque control)
x
x
x
f
72
Zero-servo command (ON: Zero-servo)
x
x
x
f
77
Speed control (ASR) proportional gain switch (ON: C5-03)
x
x
x
f
Constant Settings
User
Change
during
Setting
Factory
Valid Access Levels
User
Constant
Number
Name
g
during
Opera-
tion
Setting
Range
Unit Factory
Setting
V/f
Control
V/f with
PG
Open
Loop
Vector
Flux
Vector
H1-01
Multi-function input 1
(terminal 11)
x
0 to 77
--
24
B
B
B
B
H1-02
Multi-function input 2
(terminal 12)
x
0 to 77
--
14
B
B
B
B
H1-03
Multi-function input 3
(terminal 13)
x
0 to 77
--
3 (0)
B
B
B
B
H1-04
Multi-function input 4
(terminal 14)
x
0 to 77
--
4 (3)
B
B
B
B
H1-05
Multi-function input 5
(terminal 15)
x
0 to 77
--
6 (4)
B
B
B
B
H1-06
Multi-function input 5
(terminal 16)
x
0 to 77
--
8 (6)
B
B
B
B
D
The factory settings in parentheses are for when the Unit is initialized for 3-wire control.
D
The following table shows the settings and section references for some common functions.
Function
Setting
Section
3-wire sequence (forward/reverse run command)
0
6.1.8
Multi-step speed references 1 to 3 and jog frequen-
cy reference
3 to 6
6.1.8
Accel/Decel time 1 and 2
7, 1A
6.1.8
Emergency stop
15
6.1.8
FJOG/RJOG commands
12, 13
6.1.8
Terminal 36/39 switch
1F
6.1.8
Timer function input
18
7.5.1
Energy-saving command
63
7.2.1, 7.4.1
Local/Remote Selection (Setting: 1)
OFF
Operate with the frequency reference and run command specified in b1-01 (the frequency refer-
ence source) and b1-02 (run source).
ON
Operate with the frequency reference and run command set at the Digital Operator.
7