Switching inputs test, Ii – 2 installation set u p – HEIDENHAIN ND 287 User Manual User Manual
Page 91

ND 287
91
II – 2 Installation Set
u
p
Switching inputs test
The ND displays a list with all switching inputs at the D-sub connection
X41 (see "Switching inputs at D-sub connection X41" on page 93). The
pins are listed together with their designations, a gray/green dot and
their current states (HIGH or LOW). The function of the inputs at
connection X41
can be tested:
As soon as a pin has been activated (=LOW), the gray dot next to
the respective pin designation becomes green and the status
changes to LOW if the input functions correctly.
Danger to internal components!
The power supply of external circuits must comply with
EN 50178 requirements for low voltage electrical
separation
.
Connect inductive loads only with a quenching diode
parallel to the inductance
.
Danger to internal components!
Use only shielded cables and connect the shield to the
connector housing
.
Fig. II.56 Switching inputs test