II Installation, specifications

II – 7 Input and output of par

a

met

e

r list and er

ro

r

compensation table

Examples of parameter lists

ND 287 with rotary encoder connected to input X1

The parameter text is always sent in English.
The parameter value, not the text, is definitive when the parameters are transferred to the ND. The values in
boldface type are the default settings

.

Parameter

Meaning

#

Start character (#)

ND-287 1

DEG

Model: ND-287, Unit of measure: DEG, DMS or rad

P01

LINEAR =

0

Unit of measure for linear dimensions: mm = 0, inches = 1

P02

ANGULAR =

0

Unit of measure for angular dimensions: DEG = 0, DMS = 1, rad = 2

P03

ENC. TYPE =

1

Encoder type: Linear = 0, Rotary = 1

P04 ENC. SIGNAL =

1

Encoder signal: 0 = 11 µA, 1 = 1 Vpp, 2 = EnDat, 3 = ANALOG

P05

AXES DISPL. =

0

Display: 0 = X1, 1 = X2, 2 = X1 + X2, 3 = X1 - X2, 4 = f(X1,X2)

P06

ANGLE =

0

Angle format: 0 = +/– 180°, 1 = 360° , 2 = +/– infinity

P10

SCALING =

0

Scaling: 0 = off, 1 = on

P11 SCL. FACTOR = + 1.000000

Scale factor = 1.000000 (default setting)

P20 BRIGHTNESS =

94

Brightness of LCD screen: 0 - 100 % (80 % is the default setting)

P21

DISP. SAVER =

1

Screen saver: 0 = off, 1 = on

P22 SAVER TIME =

120

Idle time before screen saver is activated: 120 min (default setting)

P23 START.DISPL. =

1

Power-up screen: 0 = off, 1 = on

P24

SOFTKEY.X12 =

10101

Display mode selectable with SOFTKEY X1/X2: 11111 = all are activated

P30

DIRECTION =

0

Count direction: 0 = positive, 1 = negative

P31 SIGN.PERIOD =

20

Signal period: 20 µm (10 µm is the default setting)

P32

SP/R =

36000

Signal periods per revolution: 36000 is the default setting

P33 COUNT MODE =

5

Counting mode: 0 - 5 = 5, 0 - 2 = 2, 0 - 1 = 1

P34

DP PLACES =

4

Decimal places: 4 (default setting)

P35

REF ON/OFF =

1

Reference mark: 0 = off, 1 = on

P36

REF MARK =

5

0 = single reference mark

, 1..6: coded reference marks

P37

ALARM =

3

0 = off, 1 = frequency, 2 = contamination, 3 = frequency and
contamination

P38

EXT. REF =

1

External REF input: 0 = inactive, 1 = active

This manual is related to the following products: